Infectious Hypodermal and Hematopoietic Necrosis Virus Detection and
Prevention For Shrimp Farming (IHHNV nested)
|
|
Introduction:
|
|
|
Infectious Hypodermal and Hematopoietic
Necrosis Virus (IHHNV) has been wildly reported as one of the major viral
diseases in shrimp culture industry. It is known to be transmitted both
vertically and horizontally. This single strand, negative sense DNA virus can
cause mass mortality for L. stylirostris
and runt deformity syndrome (RDS) for P.
vannamei. Recent research findings pointed out that there is a close
correlation between IHHNV and muscle whitening syndrome. Although IHHNV may not
affect the growth of P. monodon
significantly, however, recent research results also pointed out that it will
influence the survival rate of the monodon broodstocks. Thus, the economic loss
cause by this virus has been underestimated for a long time.
Dr. Kathy F. J. Tang published the
IHHNV-related sequence in the genome of P.
monodom from Africa and Australia in late 2006. They developed a PCR method which can be used to differentiate
the IHHNV sequence from the IHHNV-related one in 2007. Their findings told
there is opportunity of false positive test results if tested by some
commercial PCR test kit. After our tests on the P. monodon come from Africa and Australia by our IQ2000TM IHHNV one
step PCR kit, 5% false positive results were found. However, no false positive
result is found on P. vannamei.
To rest sure of the test result on P. monodon especially come from Africa
and Australia,
we developed the IQ2000TM IHHNV (nested) Detection and Prevention System to
fulfill the requirement of the customers who need more accurate and higher
bio-security level.
With the new system, not only the false-positive
results can be avoided, but also the detection sensitivity will be increased to
10 copies per reaction same as other IQ2000 nested PCR test kits.
|
|
Specifications:
|
|
|
Packing size: 200 reactions.
Detection Limit: 10 copies/reaction.
Quantitative capability: 3 different levels of infection
can be differentiated.
Sample throughput: for 40 samples, from sample preparation
to final results require 3.5 to 4 hours.
Built-in internal control system: eliminate false negative
results from failed extraction or reaction.
Quantified positive standard: monitor the sensitivity of
detection.
Adaptable to the Uni-IQ RT-PCR profile, suitable for
multi-viral diagnosis.
|
|
Typical diagnostic
results generated by IQ2000TM IHHNV nested Detection and Prevention System.
|
|
|

Lane 1: IHHNV P(+) standard, 2000 copies/reaction
Lane 2: IHHNV P(+) standard, 200 copies/reaction
Lane 3: IHHNV P(+) standard, 20 copies/reaction
Lane 4: Sample of severe IHHNV infection
Lane 5: Sample of moderate IHHNV infection
Lane 6: Sample of very light IHHNV infection
Lane 7: IHHNV
negative sample
Lane 8: Negative control (yeast tRNA or ddH2O)
Lane M: Molecular weight marker, 848 bp, 630 bp, 333 bp
|
|
Applications:
|
|
|
Suitable for fresh,
frozen and ethanol preserved shrimp tissue samples, e.g. broodstock's eye
stalk, gill, pleopod, periopod, muscle and PL.
Ideal for SPF animal
selection, evaluation of culture environment, grow-out monitoring, and
quarantine service.